Journal of Vascular Access 2006; 7: 43 - 45 |
Azygos arch cannulation by central venous catheters for hemodialysis |
A. Granata1, M. Figuera2, S. Castellino3, F. Logias4, A. Basile2
1Department of Nephrology and Dialysis, 'Vittorio Emanuele' Hospital, Catania - Italy
2Department of Radiology, 'Vittorio Emanuele' Hospital, Catania - Italy
3Department of Nephrology and Dialysis, 'San Vincenzo' Hospital, Taormina - Italy
4Servizio Nefrologia e Dialisi, Distretto Sanitario Sorgono-Isili - Italy
ABSTRACT
Cannulation of central veins and placement of catheters for temporary haemodialysis is a common procedure in the management of patients with end stage renal failure. The internal jugular vein is the site of choice for central venous catheter placement, being associated with the lowest complication rate. This procedure can be associated with a variety of malpositions of the catheter and rarely, can lead to significant morbidity and even mortality, if this is not recognised and corrected early. For anatomical reasons, the risk of azygos arch cannulation is substan-tially increased if catheters are inserted via left-sided veins. We report a case with a rare complication associated with the insertion of a catheter for temporary haemodialysis.
Full Text, Printable Format |
|